BioQule NGS System

RevvitySKU: REV-CLS155700

Price:

Description

Reimagine low-throughput library prep with the BioQule NGS System and simplify your library prep and quantitation with walk-away automation. This low-cost, open, benchtop instrument delivers libraries ready to load into your sequencer in only 15 minutes of hands-on time (HOT), allowing you to focus on what really matters.

Currently, automated methods are available for NEXTFLEX®, Illumina®, and Roche® KAPA® kits.

Easy to Use, Compact Solution for Automating Low Throughput Library Preparation and Quantitation

  • Full walkaway automation (80% reduction in HOT)
  • Easy to use (only 4 touch points)
  • Avoid human error (>99% pass rate)
  • Open system able to automate different applications

The BioQule NGS System provides a simplified, robust walk-away solution for NGS library preparation. This system consists of a NGS preparation and quantitation instrument, cassette, and a reagent plate to generate NGS libraries. The BioQule NGS System uses an intuitive interface, automated thermal cycling, an on-board magnet, and integrated quality control through optical quantification to produce reliable NGS libraries from as little as 10 ng of starting material. The BioQule NGS System is the ideal for a lab of any size performing NGS library preparation and can easily be used by novice users to automation or NGS sample preparation.

  • Construct DNA-seq libraries from as little as 10 ng input
  • 8 libraries constructed and quantitated per run
  • Save 5 hours of hands-on timebioqule labeled

The BioQule NGS System features:

The BioQule NGS System has been specifically designed so no automation experience is required to generate NGS libraries. Simply pipette your samples, IPA, beads, and two enzymes into the plate, place the cartridge and plate in the instrument, close the door and walk-away.

This solution creates 8 NGS libraries from as little as 10 ng of starting material per run while saving 4.5 hours, on average, of hands-on time during library preparation.

The BioQule NGS System has been designed so no automation experience is required to prepare NGS libraries. Simply prepare your plate, place the cartridge and plate into the instrument, close the door and start the instrument.

Placing cartridge in instrument 1

Figure 1. Placing reagent plate in instrument 

Placing cartridge in instrument 2

Figure 2. Placing cartridge in instrument

Library Preparation & Quality Control in the Same System

The BioQule NGS System is equipped with automated fluorescence-based optical quantitation to measure the concentration of each library. You will no longer need to move your samples from one instrument to another to perform concentration analysis on your libraries.

BioQuel Image 1

The BioQule NGS System constructs libraries with size distributions that are equivalent to those prepared manually.

Manual Library Trace

A Library Prepared Manually

BioQule Library Trace

A Library Prepared with the BioQule NGS System.

  • The BioQule NGS System is now open

    The BioQule NGS System is open to automate your low-throughput library prep workflows. In addition to automating Revvity’s NEXTFLEX library prep kits, the BioQule now has automation protocols and instruction guides written for the Illumina® DNA Prep kit, with Tagmentation and the Roche® KAPA® HyperPrep kit.

    Automating Low Throughput Illumina® DNA Prep kit, with Tagmentation workflow

    The Illumina® DNA Prep kit, with Tagmentation is now automated on the BioQule NGS System to simplify and minimize human error in low-throughput WGS applications. Sequencing metrics for Illumina® DNA Prep kit WGS libraries can be seen in Figures 1 and 2. An average of 1 million reads were generated per sample (0.2x coverage). Libraries produced were a consistent size and showed minimal variability in normalized coverage across 20-60% GC. Download our application note to learn more.

    bioqule illumina fig1

    Figure 1. Insert size for a run of libraries prepared on the BioQule NGS System

     
    bioqule illumina figure 2

    Figure 2. Analysis of GC bias from the libraries obtained with Illumina® DNA Prep kit. Results show minimal variability in normalized coverage across 20-60% GC, encompassing ~ 95% of the human genome (grey bar)

     

    Automating low throughput Roche® KAPA® HyperPrep workflows

    Roche® KAPA® HyperPrep Libraries constructed using the BioQule NGS System show a consistent size and minimal variability in normalized coverage across 20-60% GC. Sequencing metrics for these WGS libraries can be seen in Figures 1-2. Download our application note to learn more.

    bioqule roche figure 1

    Figure 1. Insert size for a run of libraries prepared on the BioQule NGS System

     
    bioqule roche fig2

    Figure 2. Analysis of GC bias from the libraries obtained with the Roche® КАРА® HyperPrep kit. Results show minimal variability in normalized coverage across 20-60% GC, encompassing ~ 95% of the human genome (grey bar)

     

    BioQule library prep success rate.

    With a > 99% success rate*, the BioQule NGS delivers robust performance by minimizing error introduced by human error. Revvity defines A success was library success as:

    • a library with the expected mean size
    • with less than 3% adapter dimers
    • and library yield in excess to make a sequencing run

    Expected library size distribution was confirmed for all libraries with the LabChip® GX Touch Nucleic Acid Analyzer.

    * The success rate of libraries constructed on the BioQule NGS system is based on mean internal data. 100 samples containing 20 ng of gDNA from E. coli were used as input for NEXTFLEX® Rapid DNA-Seq Kit 2.0 automated on the BioQule NGS System.

    BioQule NGS System Compatible Kits*:

  • NEXTFLEX® Rapid DNA-Seq kit 2.0
  • NEXTFLEX® Rapid XP V2 DNA-Seq kit

     

    Other automated methods for the BioQule NGS System*:

  • Illumina® DNA Prep protocol
  • Roche® KAPA® HyperPrep protocol

    * More kits and automated methods are in development. Please inquire.
     

Simplified Reagent & Cartridge Preparation
  • Each run of the BioQule NGS System uses one reagent plate and one cartridge. The reagent plate comes pre-plated with most reagents required for NGS library preparation. Once one run is complete, simply change out the reagent plate and cartridge and you can construct another 8 NGS libraries.

    BioQule Specs 1200
    • Easy-to-use interface
    • Automated thermal cycling
    • On-board magnet
    • Integrated quality control through optical quantification
    • Easy-to-use consumable plates and cartridges
    • Easy NGS library preparation

Specifications

Depth 28.58 cm
Height 41.91 cm
Width 66.04 cm

BioQule Software and Driver Downloads

Download the software and drivers needed for the BioQule™ NGS workstation. Below you will find the latest LabChip software downloads along with their related instructions.

BioQule Software Downloads
Setup Files
Release Notes

 

BioQule Drivers
Setup Files

 

Recently viewed