{"product_id":"s220-focused-ultrasonicator","title":"S220 Focused-ultrasonicator","description":"\u003cp\u003eThe S220 Focused-ultrasonicator is a versatile, high power system engineered for pre-analytical sample processing using Covaris’ patented Adaptive Focused Acoustics® (AFA®). Utilizing a spherical acoustic transducer, specifically designed acoustical cuvettes and advanced electronics, AFA delivers controlled energy precisely and accurately to sample volumes from 15 μl to 18 ml.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/0-WEFpmLTrc\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnical Specification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePrimary Applications\u003c\/th\u003e\n\u003ctd data-th=\"Primary Applications\"\u003eCell lysis: mammalian, bacterial, yeast, cfDNA Extraction from Plasma, DNA Extraction from Dried Blood Spots, DNA\/RNA\/Chromatin Shearing, DNA\/RNA\/Total NA\/Protein Extraction from FFPE, Tissue lysis and extraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTreatment Power\u003c\/th\u003e\n\u003ctd data-th=\"Treatment Power\"\u003e100 W Avg. Incident Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePart Number\u003c\/th\u003e\n\u003ctd data-th=\"Part Number\"\u003eCOV-500217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Requirements\u003c\/th\u003e\n\u003ctd data-th=\"Power Requirements\"\u003e100-240 VAC 500 VA, 50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Environment\u003c\/th\u003e\n\u003ctd data-th=\"Operating Environment\"\u003eAmbient temperature: 19 °C to 25 °C (66 °F to 77 °F) Relative humidity: 30% to 70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd data-th=\"Operating Temperature\"\u003e19 °C to 25 °C (66 °F to 77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSafety\u003c\/th\u003e\n\u003ctd data-th=\"Safety\"\u003eComplies with Low Voltage Directive 2006\/95\/EC. Certified to IEC\/EN\/UL 61010-1:2004 “Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part1: General Requirements\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRegulatory Labeling\u003c\/th\u003e\n\u003ctd data-th=\"Regulatory Labeling\"\u003eCE, ETL Mark (for Product Safety), WEEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSonoLab Version\u003c\/th\u003e\n\u003ctd data-th=\"SonoLab Version\"\u003eSonoLab 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating System\u003c\/th\u003e\n\u003ctd data-th=\"Operating System\"\u003eWindows 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWCS\u003c\/th\u003e\n\u003ctd data-th=\"WCS\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChiller\u003c\/th\u003e\n\u003ctd data-th=\"Chiller\"\u003eChiller Required-Not included, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSample Processing Capacity\u003c\/th\u003e\n\u003ctd data-th=\"Sample Processing Capacity\"\u003eSingle tube processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNGS Sample Volumes\u003c\/th\u003e\n\u003ctd data-th=\"NGS Sample Volumes\"\u003e15 to 130 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended Batch Size\u003c\/th\u003e\n\u003ctd data-th=\"Recommended Batch Size\"\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCovaris Consumables\u003c\/th\u003e\n\u003ctd data-th=\"Covaris Consumables\"\u003emicroTUBE, milliTUBE, miniTUBE, Large volume consumables, Flow cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUpgrade Potential\u003c\/th\u003e\n\u003ctd data-th=\"Upgrade Potential\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAssociated Accessories\u003c\/th\u003e\n\u003ctd data-th=\"Associated Accessories\"\u003e\u003ca href=\"https:\/\/www.covaris.com\/products-services\/accessories\/s220-accessories\"\u003eS220 Accessories\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous Temperature Control\u003c\/li\u003e\n\u003cli\u003eNon-contact, closed vessel\u003c\/li\u003e\n\u003cli\u003eAccurate, Precise, and Controlled acoustic energy\u003c\/li\u003e\n\u003cli\u003eAccommodates a broad sample volume range\u003c\/li\u003e\n\u003cli\u003eUltrasonic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat damage, higher recovery\u003c\/li\u003e\n\u003cli\u003eNo cross contamination, no aerosols, no clean up\u003c\/li\u003e\n\u003cli\u003eProcesses and protocols are highly reproducible\u003c\/li\u003e\n\u003cli\u003eMultiple applications are accommodated in a single instrument\u003c\/li\u003e\n\u003cli\u003eAFA does not require sound-proofing or special precautions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Guides\u003c\/strong\u003e:\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/pn_010302.pdf?v=1632460150\" target=\"_blank\"\u003eDNA miniTUBE – Blue for 220 Series\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/pn_010306.pdf?v=1632460215\" target=\"_blank\"\u003eDNA miniTUBE – Clear for 220 Series\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/pn_010307.pdf?v=1632460250\" target=\"_blank\"\u003eDNA miniTUBE – Red for 220 Series\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/pn_010253.pdf?v=1632460362\" target=\"_blank\"\u003eDNA Shearing Quick Guide: microTUBE-15 with S220\/E220 Focused-ultrasonicator.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/pn_010305.pdf?v=1632460413\" target=\"_blank\"\u003eDNA Shearing with microTUBEs (\u0026lt;1.5kb fragments) S220\/E220\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/pn_010368.pdf?v=1632460525\" target=\"_blank\"\u003eDNA Shearing with S220 Focused-ultrasonicator\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/RNA_Shearing_with_S_E_and_LE-Series_Focused-ultrasonicators.pdf?v=1632460589\" target=\"_blank\"\u003eRNA Shearing with S, E, and LE-Series Focused-ultrasonicators\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManual:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/pn_010122.pdf?v=1632460739\" target=\"_blank\"\u003eS220 User Manual \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/pn_010213.pdf?v=1632460751\" target=\"_blank\"\u003eS-Series Flow Vessels Adapter Kit (500392)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePosters\u003c\/strong\u003e:\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/2012-HUPO-YinYang-Sample-Prep-Poster1.pdf?v=1632455649\" target=\"_blank\"\u003eThe Yin-Yang of Sample Preparation: Reagent optimization for maximal yield, activity, and preservation of biomarkers using Adaptive Focused Acoustics®(AFA®)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/2012-HUPO-Phosphoprotein-Poster.pdf?v=1632455687\" target=\"_blank\"\u003eRobust pre-analytical sample preparation process preserves the accuracy and fidelity of protein phosphorylation states\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/HUPO-2018-ProtiFi-Covaris-Poster.pdf?v=1632460906\" target=\"_blank\"\u003eUniversal Sample Processing Of Multiple Sample Types For Reproducible Proteomic Sample Preparation\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrochures\u003c\/strong\u003e:\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/M020011.pdf?v=1632460949\" target=\"_blank\"\u003eS220\/S220x\/S220R Focused-ultrasonicator\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/files\/M020123.pdf?v=1632460983\" target=\"_blank\"\u003eFormulation and Drug Delivery Breakthrough processing for poorly soluble API’s\u003c\/a\u003e\u003c\/p\u003e","brand":"Covaris","offers":[{"title":"COV-500217","offer_id":39365583798316,"sku":"COV-500217","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0377\/2163\/6908\/products\/500217_0.png?v=1744735214","url":"https:\/\/dmarkbio.com\/products\/s220-focused-ultrasonicator","provider":"DMark","version":"1.0","type":"link"}